Normalization of Laser-induced Breakdown Spectroscopy Using Laser-ablation-induced Ultrasonic Body Waves
Author:
Affiliation:

Fund Project:

undefined

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
    Abstract:

    Shot-to-shot fluctuations in laser-induced plasma emission limit the precision of quantitative laser-induced breakdown spectroscopy (LIBS). This study evaluates an ultrasonic-assisted normalization approach in which laser-ablation-induced body waves, measured with a contact piezoelectric transducer, are used as an external indicator of shot-dependent ablation variability. For each analyte, the first-arrival acoustic feature was related to the within-specimen relative deviation of the corresponding emission line using a single model fitted from pooled calibration data; the fitted coefficients were then applied unchanged to the prediction specimens. For Mn, Cr, and Cu, normalization reduced the shot-to-shot relative standard deviation (RSD) from 6.87%, 4.27%, and 4.59% to 2.30%, 2.25%, and 2.87%, respectively. The corresponding average relative errors decreased from 1.41% to 1.13% for Mn, from 2.27% to 2.02% for Cr, and from 1.04% to 0.93% for Cu. For comparison with spectral internal standardization, Fe-dominant reference features were selected from the averaged spectra using spectral non-overlap, monotonic calibration behavior, calibration-set R2 and RMSEC, and calibration-sample RSD; prediction metrics were not used during feature selection. The selected reference features were 391.843, 427.966, and 458.218 nm for Mn, Cr, and Cu, respectively. Both the optimized Fe-ratio and ultrasonic-normalized models improved quantitative performance relative to the raw-intensity models, although the extent of improvement depended on the analyte and evaluation metric. Additional measurements showed that the body-wave response is sensitive to mechanical coupling and specimen thickness, while a synchronous comparison with an airborne-acoustic channel showed distinct temporal and statistical characteristics. Accordingly, the contact body-wave approach can serve as a configuration-dependent external reference when stable mechanical coupling can be maintained.

    Reference
    Related
    Cited by
Get Citation

Yuhua Hang, Jinliang Zhao, Shuhao Fan, Lu-Ning Li, Wei-Ming Xu, Rong Shu, Jinna Mei, Yan Qiu*. Normalization of Laser-induced Breakdown Spectroscopy Using Laser-ablation-induced Ultrasonic Body Waves[J]. Atomic Spectroscopy,2026,47(5):629-638.

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: October 07,2026
  • Published:
Copyright © 2026 Atomic Spectroscopy Press Ltd All rights reserved
Supported by:Beijing E-Tiller Technology Development Co., Ltd.