Data-provenance-aware Stark Broadening Estimation for Automated LIBS Spectral Simulation of Ionic Lines
Author:
Affiliation:

Fund Project:

undefined

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
    Abstract:

    Laser-induced breakdown spectroscopy (LIBS) simulation requires accurate Stark-width parameters, yet reliable data remain missing for many spectral lines. Current simulators rely mainly on manually maintained tables, simplified analytical formulas, or the STARK-B database — but manual curation is labor-intensive, simplified formulas carry large errors, and STARK-B covers a limited set of lines on a discrete, pre-computed temperature grid. To bridge these gaps, an automated ion-line Stark-width workflow was developed based on the modified semi-empirical (MSE) method on top of the NIST Atomic Spectra Database, with the required oscillator strengths completed through a tiered hierarchy of sources. The MSE formalism is defined for ionized emitters, and the workflow inherits that domain. Each computed width is returned with an uncertainty estimate and a full data-provenance trace, and widths resting on weak inputs are automatically flagged as high-risk. The workflow is accessible through both a web interface and a Python SDK, making Stark widths available at the scale that spectrum-level LIBS applications require. The workflow is validated against two independent references: the semiclassical STARK-B database and the critically evaluated measured widths of Konjevi? et al. (2002). The MSE formalism itself, applied with hand-curated inputs, carries a stated accuracy of about 50 %; the automated workflow trades part of this precision for coverage, since oscillator strengths are completed from external databases and statistical estimates rather than curated line by line, and sparse level data leave some widths to the approximate lumped term. Within the LIBS-relevant scope of ions II–IV in the optical window, the median ratios of computed to reference widths (W_MSE/W_ref) are 1.15 against STARK-B (802 per-condition comparisons) and 1.05 against the evaluated measurements (1,159 per-condition comparisons). Of these comparisons, 62 % and 58 % respectively fall within a factor of 1.5, and 83 % and 76 % within a factor of two. This provides the basis for obtaining Stark widths at the scale LIBS applications demand, and the identified error sources define clear routes for refining the accuracy. A dedicated treatment of the neutral emitters, the prerequisite for serving a full-spectrum LIBS simulator, is the largest single item of future work.

    Reference
    Related
    Cited by
Get Citation

Yilin Wang*, Toni Aaltonen*, Shuo Zhang. Data-provenance-aware Stark Broadening Estimation for Automated LIBS Spectral Simulation of Ionic Lines[J]. Atomic Spectroscopy,2026,47(5):765-776.

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: October 07,2026
  • Published:
Copyright © 2026 Atomic Spectroscopy Press Ltd All rights reserved
Supported by:Beijing E-Tiller Technology Development Co., Ltd.